<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Article Tag Suite 1.1//EN"
  "https://jats.nlm.nih.gov/publishing/1.1/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink"
         xmlns:mml="http://www.w3.org/1998/Math/MathML"
         article-type="research-article"
         xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>American Journal of PharmTech Research</journal-title>
        <abbrev-journal-title abbrev-type="publisher">AJPTR</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">2249-3387</issn>
      <publisher>
        <publisher-name>undefined</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">AJPTR71029</article-id>
      <title-group>
        <article-title>Estimation of Lidocaine-HCl in  Pharmaceutical drugs by HPLC-UV System</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Al-Salman</surname>
            <given-names>H. N. K.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Al-Jadaan</surname>
            <given-names>Shaker A. S.</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Al-Nuaim</surname>
            <given-names>Maan</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Hussein</surname>
            <given-names>Hussein H.</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub" iso-8601-date="2017-02-01">
        <month>02</month>
        <day>01</day>
        <year>2017</year>
      </pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <abstract>
        <p>An accurate, precise and sensitive HPLC system is used to determination of Lidocaine-HCl in vial dosage form as parenteral solution (intra-muscular), to compare with two Lidocaine-HCl form; commercial formulations and standard Lidocaine-HCl high purity as a test formulation. Lidocaine-HCl concentrations were analyzed by a HPLC-UV System (λ = 254 nm) at 25 o C. The separation was achieved using the Ion Pac Ercus C18 RP-Column; 5µm, (250×4.5 mm id). The mobile phase consisted of acetonitrile/ water (20/80) with 5% acetic acid at pH 3.4. The method was found to be linearity in the range (0.1 to 0.5) µg/ml (n = 5) with R2 ≥ 0.9987, also, the recoveries were range within 96.0-100%. The detection limit of quantification (LLOQ) was 0.01645 µg/ml and lower limit of detection (LLOD) 0.00521 µg/ml. showing average intra assay and inter-assay coefficients of ± RSD % about 0.526 %. The standard Lidocaine-HCl drug eluted at a flow rate of 1.0 ml/min. The results of recoveries, ± RSD, and statistical parameters obtained in this study, clearly indicated that the HPLC–UV system offer a successfully and excellent method for the separation and determination of Lidocaine-HCl in the commercial drugs.      </p>
      </abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Lidocaine-HCl as parenteral solution (intra-muscular) and Standardized</kwd>
        <kwd>HPLC- UV System.</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <!-- Full article body not available in metadata-only JATS export. See PDF/HTML galley. -->
  </body>
  <back/>
</article>