RP-HPLC Stability Indicating Analytical Method Development and Validation For The Simultaneous Estimation Of Tezacaftor, Ivacaftor and Elexacaftor In API and Pharmaceutical Dosage Form

Published in February 2024 Issue 1 (Vol. 14, Issue 1, 2024)

RP-HPLC Stability Indicating Analytical Method Development and Validation For The Simultaneous Estimation Of Tezacaftor, Ivacaftor and Elexacaftor In API and Pharmaceutical Dosage Form - Issue cover

Abstract

We developed a straightforward, precise method for the simultaneous estimation of Ivacaftor, Elexacaftor and Tezacaftor in both bulk and tablet dosage forms. The chromatography analysis was performed using a Discovery C18 column measuring 150 x 4.6 mm with a 5µm particle size. The mobile phase, composed of Acetonitrile: Methanol: 0.1% OPA (10:35:55 v/v) was pumped at a flow rate of 0.9 ml/min, with the temperature maintained at 28°C. The optimized wavelength for detecting 3 drugs was set at 278.0 nm. Retention times were measured at 2.537 min, 2.089 min, and 3.090 min, respectively. The method precision showed low %RSD values, with 0.4 for Ivacaftor, 0.3 for Elexacaftor and 0.4 for Tezacaftor. Recovery percentages were determined as 99.79% for Ivacaftor, 99.72% for Elexacaftor and 100.05% for Tezacaftor. Furthermore, the LOD and LOQ values derived from the regression equations for  Ivacaftor, Elexacaftor and Tezacaftor i.e  y = 22674x + 2799.3, y = 21285x + 4513.2 and y = 21548x + 869.63  were found to be 0.06 ppm and 0.22 ppm, 0.18 ppm and 0.19 ppm , 0.07 ppm and 0.57 ppm  respectively. With reduced retention times, this method offers simplicity and cost-effectiveness, making it suitable for routine quality control testing.

Citations & discovery

Explore citations to this article and find it in scholarly databases.

Crossref
…
Citations
View record
Europe PMC
…
DOI matches
View results
Google Scholar

Checking citation sources…

Citation counts reflect each source's coverage. Europe PMC shows DOI search matches, including mentions in references. Article lists may be incomplete. Google Scholar opens a separate search.

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Summarise this paper with AI:

Article Information

AJPTR141001

AJPTR-01-002346

1-19

2024-02-01

JATS XML

Article Impact

Views:3,125
Downloads:1,339
scite_
PlumX Metrics Badge

How to Cite

Divya, M., Vinutha, K., Sridevi, P., & Bhagawan Raju, M. (2024). RP-HPLC Stability Indicating Analytical Method Development and Validation For The Simultaneous Estimation Of Tezacaftor, Ivacaftor and Elexacaftor In API and Pharmaceutical Dosage Form. American Journal of PharmTech Research, 14(1), 1-19. https://doi.org/10.5281/zenodo.10691639

Article Actions

Whatsapp