Skip to main content
editor@ajptr.com
9409046853
e-ISSN: 2249-3387
American Journal of PharmTech Research

American Journal of PharmTech Research

Published

Development and Validation for the Determination of Related Substance in Irinotecan HCl formulation and its Stability Indicating Assay by RP- HPLC method

Published in August 2013 Issue 4 (Vol. 3, Issue 4, 2013)

Development and Validation for the Determination of Related Substance in Irinotecan HCl formulation and its Stability Indicating Assay by RP- HPLC method - Issue cover

Abstract

A simple isocratic RP-HPLC stability indicating method has been developed and subsequently validated for the determination of Irinotecan HCl and its related substance (SN-38) in pharmaceutical dosage forms as per ICH guidelines. The separation achieved on a reversed phase Phenomenex Luna C18 Column (5µ, 250 × 4.60 mm) as a stationary phase and 0.5% trichloro acetic acid: Acetonitrile: Methanol (60: 20: 20 v/v/v) as mobile phase at a flow rate of 1.0 ml/min. The UV detection was performed at 372 nm.  The retention time for Irinotecan HCl and SN-38 was found to be 8.65 and 7.30 min respectively. The detector response was linear in the concentration range of 30-150 µg/ml. The respective linear regression equation being Y= 5233.x + 13299 with R2 = 0.999. The percentage of Irinotecan HCl in pharmaceutical dosage form was found to be 100.5% and the percentage of related substance (SN-38) in formulation was found to be 0.19%. The limit of detection and the limit of quantification were found to be 0.014 µg/ml and 0.045 µg/ml respectively. The results of the study showed that, the proposed RP-HPLC method was simple, rapid, precise, accurate and stability indicating, which can be used for the routine determination of Irinotecan HCl and its related substance (SN-38) in pharmaceutical dosage form.

Authors (3)

Rajasekaran Aiyalu

View all publications →

Rambabu Cherukuri

View all publications →

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Summarise this paper with AI:

Article Information

AJPTR34050

AJPTR-01-000845

2013-08-01

JATS XML

Article Impact

Views:4,501
Downloads:2,162

How to Cite

Aiyalu & Cherukuri & Joghee (2013). Development and Validation for the Determination of Related Substance in Irinotecan HCl formulation and its Stability Indicating Assay by RP- HPLC method. American Journal of PharmTech Research, 3(4), xx-xx. https://ajptr.com/articles/AJPTR34050

Article Actions

Whatsapp